##Pour antifreeze in all drain and toilet traps to keep sewer gases trapped. | ##Pour antifreeze in all drain and toilet traps to keep sewer gases trapped. | ||
##Turn heating system thermostat to low or off, depending on your decision. | ##Turn heating system thermostat to low or off, depending on your decision. | ||
===Re-opening a winterized house=== | |||
#Air out the house immediately, in case sewer gases built up. | |||
#Open a faucet or two, especially high in your house, to help air escape while you re-fill the pipes. The less air, the less the system will bang and spurt later. | |||
#Turn on the circuit for the water pump. | |||
#Turn on cold water supply. | |||
#Turn on the water supply to the water heater. | |||
##Check to see if there are any leaky pipes. If so, there may have been ice in them which may have burst the pipes. Consider PEX piping. | |||
##Close the faucets you used to release the air. | |||
#Open and close all faucets and flush all toilets to release the air from all the branches of the pipes. | |||
#Only when the entire system is flushed with water turn on the water heater. | |||
#Turn on the house-heating system as needed. |
Revision as of 14:14, 10 June 2010
I developed this list when shutting down the cabin in Maine.
- To prevent pipes from freezing and critters from entering a house, follow these steps
- Remove exterior screens.
- Place with storm windows if available.
- Lock every window and door.
- Turn off water heater before turning off water. For electric heaters, turn off circuit breaker. For gas, follow specific instructions.
- Turn off circuit breakers to everything but important lights and security system. If there's a breaker to a water pump, turn it off.
- Turn off water.
- Drain water pipes (after water heater is turned off):
- Attach hose to drain, and/or bottom of water heater. Lead hose outside or to a drain lower than everything else.
- Shut off water supply to house.
- Open drain valve attached to hose.
- Open all faucets, valves. If you have a single knob for both hot and cold, as in a shower mixing valve or kitchen faucet, set it to the middle position so both hot and cold drain.
- Flush all toilets, keeping handle held down while pipes drain.
- Wait two minutes or until there's no more flow.
- Close all but one valve, leaving one slightly open over a sink to allow air and trace water to expand and contract.
- Pour antifreeze in all drain and toilet traps to keep sewer gases trapped.
- Turn heating system thermostat to low or off, depending on your decision.
Re-opening a winterized house
- Air out the house immediately, in case sewer gases built up.
- Open a faucet or two, especially high in your house, to help air escape while you re-fill the pipes. The less air, the less the system will bang and spurt later.
- Turn on the circuit for the water pump.
- Turn on cold water supply.
- Turn on the water supply to the water heater.
- Check to see if there are any leaky pipes. If so, there may have been ice in them which may have burst the pipes. Consider PEX piping.
- Close the faucets you used to release the air.
- Open and close all faucets and flush all toilets to release the air from all the branches of the pipes.
- Only when the entire system is flushed with water turn on the water heater.
- Turn on the house-heating system as needed.